External Publication
Visit Post

First Physics Audit of Open-X Embodiment — 216 Episodes, 78.1% Pass Rate

Hugging Face Forums [Unofficial] March 12, 2026
Source

First Physics Audit of Open-X Embodiment — 216 Episodes, 78.1% Pass Rate

I built a tool that applies biomechanical physics laws to sensor data before training.

No ML. No learned classifier. Just equations — F=ma coupling, rigid-body kinematics,

jerk bounds, Hurst persistence.

I ran it on RoboTurk from Open-X Embodiment. Here is what came out.

-–

The Audit

Dataset: RoboTurk (Open-X Embodiment, Stanford)

Episodes: 216 human-teleoperated demonstrations

Windows certified: 1,143

| Tier | Count | % |

|------|-------|—|

| GOLD | 284 | 24.8% |

| SILVER | 609 | 53.3% |

| BRONZE | 242 | 21.2% |

| REJECTED | 8 | 0.7% |

Pass rate (GOLD+SILVER): 78.1%

Top failing law: imu_internal_consistency — 32.4% of windows

-–

What the Finding Means

imu_internal_consistency checks that translational acceleration and rotational

acceleration are physically coupled — as they are in real human motion.

In RoboTurk, world_vector (translation) and rotation_delta (rotation) are

commanded through separate channels in the smartphone teleoperation interface.

They have different latencies. S2S detects this mismatch.

This is not a bug in the data. It is a measurable property of the teleoperation

interface — and S2S quantifies it. 32.4% of windows have translational and

rotational commands that are physically inconsistent with each other.

For robot training: a model trained on these windows learns motion where the

hand translation and wrist rotation are decoupled. That is not how humans move.

-–

Comparison to Real Human IMU

| Dataset | Pass Rate | Top Law |

|---------|-----------|---------|

| NinaPro DB5 (real human, 2000Hz) | 100% SILVER | none |

| RoboTurk (teleoperation, 15Hz) | 78.1% | imu_consistency 32.4% |

Real human IMU passes everything. Teleoperation data has a measurable quality gap.

-–

Reproduce It


pip install s2s-certify

git clone GitHub - timbo4u1/S2S: Physics certification for robot training data. Checks 11 biomechanical laws before your model trains. · GitHub

cd S2S && python3 certify_roboturk.py

Full audit data: Scan2s/s2s-certified-motion · Datasets at Hugging Face

-–

This is the first physics audit of Open-X Embodiment I am aware of.

If anyone has run similar analysis on other Open-X subsets I would like to know.

The tool works on any IMU/EMG dataset. Zero dependencies. Pure Python.

Discussion in the ATmosphere

Loading comments...